Raypak Boiler 300 850 User Guide

XFyre- Type H  
Condensing Heating Boilers  
Models 300-850  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Date:  
Indoor/Outdoor:  
Up to 94% Thermal Efficiency at Full Rate  
100% Factory Fire Tested  
Maximum Outlet Water Temperature: 210°F  
Maximum System Temperature: 200°F  
Full Safety Diagnostics with History  
Footprint: Less Than 9-1/2 ft2  
Limited Twenty-Year Thermal Shock Warranty  
Limited Ten-Year Heat Exchanger Warranty  
Full Electronic Modulation, Constant Ratio 5:1 Turndown  
Soft-Start Modulating Controller with LCD Display  
Status and Full Diagnostics Display  
Heat Exchanger  
ƒ All Stainless Steel Construction  
ƒ Gasketless Heat Exchanger Design  
ƒ ASME H Stamped  
160 PSIG Working Pressure  
ƒ National Board Approved  
ƒ ASME Pressure Relief Valve  
Multi-Boiler System Controllers  
B-36 TempTracker Mod+ Digital  
Controller, 2-4 Boilers, OA Reset  
B-37 TempTracker Mod+ Digital  
Controller, 5-10 Boilers, OA Reset  
B-38 TempTracker Mod+ Digital  
Controller, 11-16 Boilers, OA Reset  
Gas Train  
ƒ Fuel  
Natural Gas  
Propane  
ƒ Zero Governor Regulator  
ƒ Dual-Seat Combination Valve  
ƒ Electronic Modulating Firing Mode (H7)  
60 PSIG – Standard  
Options  
PSIG – Optional  
ƒ Temperature and Pressure Gauge,  
Shipped Loose  
Construction  
D-21 TruSeal™ Combustion Air Inlet  
ƒ Indoor/Outdoor Construction  
ƒ Front Controls Enclosed  
ƒ PolyTuf Powder Coat Finish  
ƒ Rear Connections (Electrical, Gas, Vent,  
Combustion Air)  
ƒ Top Connections (Water)  
ƒ Design Certified ANSI Z21.13/  
CSA 4.9  
P-  
Pump:  
Cast Iron  
HP, 120V, 1, 60Hz  
Bronze  
Control  
S-1  
S-2  
Low Gas Pressure Switch,  
Manual Reset  
High Gas Pressure Switch,  
Manual Reset  
ƒ 120V, 60Hz, 1Ø, Power Supply  
ƒ Digital Operating Control with LCD  
display.  
ƒ Outdoor reset with Indirect Priority  
ƒ 0-10 VDC input for BMS  
ƒ Cascade up to 8 boilers  
ƒ Spark Ignition (IID)  
ƒ Remote Flame Sensor  
ƒ High Limit, Manual Reset, Fixed,  
200ºF  
Z-12 Condensate Neutralizer Kit  
Venting (PVC-CPVC-Stainless.)  
ƒ Vent Termination  
Indoor, Vertical – Option D-11  
Indoor, Horizontal – Option D-15  
Outdoor  
Regulatory Agency Requirements  
ƒ Auto Limit, Fixed, 210ºF  
ƒ Alarm Dry Contact Connection  
ƒ On/Off Power Switch  
ƒ Flow Switch  
ƒ Extractor - Optional  
By others  
Not required  
ƒ Blocked Vent Pressure Switch  
ƒ Boiler, DHW & System Pump  
Contacts  
ƒ Water Temperature Sensors (3)  
Burner  
ƒ Ultra-Low NOx: Less than 20 PPM  
Catalog No.: 2000.17  
Effective: 6-22-09  
Replaces: New  
 

PYLE Audio Turntable PVNTT6UM User Guide
Radio Shack GPS Receiver PLNV430 User Guide
Radio Shack Handheld TV 16 173 User Guide
Radio Shack Speaker 40 293 User Guide
RCA MP3 Player TC160 User Guide
RedMax Trimmer LRTZ2401 User Guide
RIDGID Welder kt 190 User Guide
Saab Air Conditioner 9 3 M03 User Guide
Sanyo Flat Panel Television DP32D13 User Guide
Satco Products Indoor Furnishings 76 280 User Guide