1. Installation  
Do not connect the E8a module until the software support has been installed.  
1. Insert the CD into your computer’s CD-ROM drive. The CD should automatically run the installation program. If  
the installer does not start, browse to the RSK directory from the CD root folder and double click on ‘setup.exe’.  
2. The installer will ask you which language is to be used, please choose the appropriate one.  
3. On the first screen of the installer proper, click <Next>.  
4. The License Agreement will be shown, click <Yes>.  
5. The next screen asks you to pick the world region – please select and click <Next>.  
6. Select the RSK you wish to install and click <Next>.  
7. The destination folders are specified on the next screens. It is recommended to accept the default settings.  
Click <Next> to continue.  
8. Click <Next> on all screens until the Installation process commences.  
9. After the installation the machine’s site code will be shown, this is not important at this stage, click <Next> then  
<Finish>.  
10. Auto update dialog box will be launched. Configure the Auto-Update settings dialog to allow your installation to  
be checked for required updates.  
D006364_11_S01_V04  
 
4. Programming and Debug  
27. Ensure the “SessionH8_SLP_E8a_SYSTEM_300L”  
session in the right hand drop down list on the toolbar is selected.  
28. Click the <Connect> button on the debug toolbar.  
29. Select the correct device type (e.g. H8/38347F for  
RSKH838347).  
30. Select “Erase Flash and Connect”.  
31. Select “Power target from Emulator” and select “5V” if the  
E8 is to provide the power to the RSK board. Otherwise  
connect a 5V center positive supply.  
32. Click <OK>.  
33. The first time the E8a is used  
the “E8AH8” dialog appears,  
click  
<OK>  
and  
select  
“Renesas Communications”  
and click <Close>.  
Otherwise skip to the next  
step.  
34. Accept any dialog warning that an older version of E8a firmware is necessary to work with the application. Allow  
download of firmware to complete, this may take several seconds.  
35. Fist, select the clock speed (“16.00MHz” for the  
RSKH838347) then click <OK>.  
36. Second, select the ID Code (“0E8A” for the  
RSKH838347) then click <OK>. The flash memory write  
program and E8a monitor are then downloaded to the microcontroller.  
37. Right click on the download module listed in  
the left hand pane and select “Download”.  
The code will be downloaded to the  
microcontroller. This may take several  
seconds.  
38. Click the <Reset Go> button.  
The code will run and you will see the LEDs flash on the board.  
39. Click the <Stop> button.  
The code will stop and the source code will be opened at the current program counter.  
D006364_11_S01_V04  
 
5. Next Step  
After you have completed this quick start procedure, please review the tutorial code and sample code that came with  
the kit. You can add projects to the current workspace by selecting (Project > Insert Project) from the main menu.  
The tutorials will help you understand the device and development process using Renesas Development Tools.  
The Hardware manual supplied with this RSK is current at the time of publication. Please check for any updates to  
the device manual from the Renesas website at: www.renesas.com/renesas_starter_kits  
6. Renesas H8 Compiler  
The version of the compiler provided with this RSK is fully functional but time limited. You have 60 days to evaluate  
the full product before the compiler will limit the code linker to 64k bytes. Full licensed H8 compiler versions are  
available from your Renesas supplier.  
7. Support  
Online technical support and information is available at: www.renesas.com/renesas_starter_kits  
Technical Contact Details  
America:  
Europe:  
Japan:  
Note on Autoupdate: The Autoupdater is configured to automatically add itself to the Startup folder in the  
Windows Start Menu and use the registry defaults for access to the web. After restarting the machine the Icon  
will appear in the System Tray next to the clock. To change the settings or access Autoupdate simply right-click  
on the icon and use the menu that appears.  
© Renesas Solutions Corporation. 2007.  
© Renesas Technology Corporation. 2007.  
© Renesas Technology Europe Limited. 2007.  
D006364_11_S01_V04  
 

PYLE Audio Stereo Amplifier PHA80 User Guide
RadioLAN Appliance Trim Kit 52TA1472 User Guide
Radio Shack PDAs Smartphones 65 773 User Guide
Radio Shack Portable Radio PRS 102 UHF User Guide
Radio Shack Weather Radio 12 240 User Guide
Rheem Portable Generator GEN 30B User Guide
Samsung Blu ray Player 01963B User Guide
SanDisk MP3 Player TakeTV User Guide
Savin All in One Printer 9027 User Guide
SBC comm Cordless Telephone SBC 6020 User Guide