R0E330850MSRC0
Emulation Memory Board for M32C/80 Series Compact Emulator
User’s Manual
Keep safety first in your circuit designs!
z Renesas Technology Corporation and Renesas Solutions Corporation put the maximum effort into making semiconductor products
better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to
personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with
appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention
against any malfunction or mishap.
Notes regarding these materials
z These materials are intended as a reference to assist our customers in the selection of the Renesas Technology product best suited
to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to
Renesas Technology Corporation, Renesas Solutions Corporation or a third party.
z Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any damage, or infringement of
any third-party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application
examples contained in these materials.
z All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information
on products at the time of publication of these materials, and are subject to change by Renesas Technology Corporation and
Renesas Solutions Corporation without notice due to product improvements or other reasons. It is therefore recommended that
customers contact Renesas Technology Corporation, Renesas Solutions Corporation or an authorized Renesas Technology product
distributor for the latest product information before purchasing a product listed herein. The information described here may contain
technical inaccuracies or typographical errors. Renesas Technology Corporation and Renesas Solutions Corporation assume no
responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information
published by Renesas Technology Corporation and Renesas Solutions Corporation by various means, including the Renesas home
page (http://www.renesas.com).
z When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and
algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the
information and products. Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any
damage, liability or other loss resulting from the information contained herein.
z Renesas Technology semiconductors are not designed or manufactured for use in a device or system that is used under
circumstances in which human life is potentially at stake. Please contact Renesas Technology Corporation, Renesas Solutions
Corporation or an authorized Renesas Technology product distributor when considering the use of a product contained herein for any
specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
z The prior written approval of Renesas Technology Corporation and Renesas Solutions Corporation is necessary to reprint or
reproduce in whole or in part these materials.
z If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from
the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport
contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
z Please contact Renesas Technology Corporation or Renesas Solutions Corporation for further details on these materials or the
products contained therein.
Precautions to be taken when using this product
z This product is a development supporting unit for use in your program development and evaluation stages. In mass-producing your
program you have finished developing, be sure to make a judgment on your own risk that it can be put to practical use by performing
integration test, evaluation, or some experiment else.
z In no event shall Renesas Solutions Corporation be liable for any consequence arising from the use of this product.
z Renesas Solutions Corporation strives to renovate or provide a workaround for product malfunction at some charge or without charge.
However, this does not necessarily mean that Renesas Solutions Corporation guarantees the renovation or the provision under any
circumstances.
z This product has been developed by assuming its use for program development and evaluation in laboratories. Therefore, it does not
fall under the application of Electrical Appliance and Material Safety Law and protection against electromagnetic interference when
used in Japan.
WARNING indicates a potentially dangerous situation that will cause
death or heavy wound unless it is avoided.
WARNING
CAUTION indicates a potentially dangerous situation that will cause
a slight injury or a medium-degree injury unless it is avoided.
CAUTION
This is used in operation procedures or explanatory descriptions to
convey exceptional conditions or cautions to the user.
IMPORTANT
Rev.1.00
Oct. 01, 2006
(1/4)
REJ10J1122-0100
4. Usage (Emulator Debugger)
The required operating environment is described below.
- Integrated development environment:
- Emulator debugger:
High-performance Embedded Workshop
M32C Compact emulator debugger Ver.1.00 Release 00 or later
(The emulator debugger “M3T-PD308MF” can not be used.)
Set the emulation memory in the Emem dialog box of the emulator debugger start-up.
1. Specifying the processor mode
Specifying the processor mode
Select the appropriate processor mode that suits your system.
2. Emulation memory allocation for an extended area
Emulation memory allocation for an extended area
When memory expansion or microprocessor mode is selected, emulation memory can be
allocated to the extended area to be debugged (in up to four areas).
* Bank (Set bank address)
Specify the bank address of the debug target area to be allocated in hexadecimal. If
specified as d0, D00000h is the start address of the debug target area.
* Length (Specify size of area)
Specify the size of the debug target area (256Kbytes or 1Mbytes). If Length is specified
to be “256Kbytes”, banks 00, 04, 08, and up to FC (every four banks) are specified for
Bank; if Length is specified to be “1 Mbytes”, banks 00, 10, 20 and up to F0 (every 16
banks) are specified for Bank.
* Map (Specify area map)
Specify the mapping information (“Internal” or “External”) in the specified area. If no area
is specified, select “No Use”
- Internal : The area specified to be “Internal” is mapped into the internal area (emulation
memory).
- External : The area specified to be “External” is mapped into the external area (external
resource in the user system)
IMPORTANT
Notes on Selecting a Processor Mode of the M30850T3-CPE:
z When setting single-chip mode, do not connect to this product.
z When setting memory expansion mode, the level of the pin CNVSS of the MCU status should be "L".
z When setting microprocessor mode, the level of the pin CNVSS of the MCU status should be "H".
z When setting memory expansion mode or microprocessor mode, the level of the pins RDY# and HOLD# of the MCU status
should be "H".
Notes on Using Expansion Emulation Memory:
z MCU internal resources are automatically selected as SFR and RAM areas regardless of settings.
z For a reset vector area, memory of the emulator is always selected regardless of the setting
z When memory expansion mode is set as a processor mode, internal ROM area is automatically allocated to the internal
Flash memory. Therefore, it is not necessary to deliberately specify expansion emulation memory in order to allocate the
internal ROM area.
z The 4MB memory mounted in the product can be allocated to the external area. Set memory allocation so that the total of
the 4 Length values does not exceed the emulation memory size (4MB). However, the emulation memory is 3.25MB in
memory expansion mode.
z Be careful that the specified areas do not overlap one another.
z Except for the SFR, RAM, ROM and internally reserved areas, all areas other than the set area are externally accessible.
z In Map, the areas where “No Use” is selected, and is unspecified are allocated to external resources. When “External” is
specified, only the downloaded speed is different.
z Do not set the following areas for memory allocation of the MCU. Set these areas referring the specifications of the MCU.
(1) Area allocated for multiplex bus (2) Unusable area
(3/4)
5. Specifications
Applicable compact emulator
M30850T3-CPE
4Mbytes
Size of emulation memory installed
Applicable MCU mode
Memory expansion mode, Microprocessor mode
3.0 to 5.5 V
1Ø+1Ø : 32MHz*
Memory expansion mode: Maximum 3.25Mbytes
Microprocessor mode: Maximum 4.00Mbytes
Applicable power supply
Maximum operating frequency
Emulation memory allocation
*The restrictions in this product operating frequency depend on VCC2 power voltage.
(These restrictions only need to be observed when using an emulator.) (See Figure 2)
Intelligent I/O 1wait read access
Intelligent I/O 2wait (set the PM13 bit to "1") read access
Operating
frequency
[MHz]
Operating
frequency
[MHz]
32
24
24
VCC2
voltage[V]
VCC2
voltage[V]
0
3.0
5.5
0
3.0
4.2
5.5
Figure 2 Restrictions in operating frequency when using this product
(When using in single-power supply: VCC1 = VCC2, When using in dual-power supply: VCC1 = 5.0 ± 0.2 [V] fixed)
6. Precautions
WARNING
Warnings to Be Taken for This Product:
z Do not disassemble or modify this product. Personal injury due to electric shock may occur if this product is
disassembled and modified. Disassembling and modifying the product will void your warranty.
Warning for Installation:
z Do not set this product in water or areas of high humidity. Make sure that the product does not get wet. Spilling
water or some other liquid into the product may cause unrepairable damage.
Warning for Use Environment:
z This equipment is to be used in an environment with a maximum ambient temperature of 35°C. Care should be taken
that this temperature is not exceeded.
CAUTION
Cautions to Be Taken for This Product:
z Use caution when handling this product. Be careful not to apply a mechanical shock.
z Do not touch the connector pins of this product directly. Static electricity may damage the internal circuits.
Caution to Be Taken for System Malfunctions:
z If the emulator malfunctions because of interference like external noise, do the following to remedy the trouble.
(1) Press the RESET button on the emulator upper panel.
(2) If normal operation is not restored after step (1), shut OFF the emulator once and then reactivate it.
Caution to Be Taken for Using with M30850T2-CPE and M30870T2-CPE:
z Do not use this product with M30850T2-CPE and M30870T2-CPE.
7. Inquiries
For inquiries about this product or the contents of this manual, contact your local distributor.
(4/4)
|