Seagate Computer Monitor ST31250N ND User Guide

BARRACUDA 2LP  
Disc Drive  
ST31250N/ND  
ST31250W/WD/WC/DC  
ST32550N/ND  
ST32550W/WD/WC/DC  
Installation Guide  
 
Barracuda 2LP Installation Guide, Rev. E  
1
Preface  
This manual contains information for users of the  
Seagate® ST31250andST32550Barracuda2LPSCSI  
disc drives. It provides support services, performance  
specifications, and initial setup information. Additional  
information is available in the Barracuda 2LP Product  
Manual(partnumber83328930).Contact yourSeagate  
sales representative if you need to order this publica-  
tion.  
Electrostatic discharge protection  
Caution. Removal of circuit boards by personnel not  
performing depot repair will damage compo-  
nents and may void the warranty.  
All drive electronic assemblies are sensitive to static  
electricity, due to the electrostatically sensitive devices  
used within the drive circuitry. Although some devices  
such as metal-oxide semiconductors are extremely  
sensitive, all semiconductors, aswell as some resistors  
and capacitors, may be damaged or degraded by expo-  
sure to static electricity.  
Electrostatic damage to electronic devices may be  
caused bythedirectdischargeofachargedconductoror  
by exposure to the static fields surrounding charged  
objects. To avoid damaging drive electronic assemblies,  
observe the following precautions when installing or  
servicing the drive:  
 
2
Barracuda 2LP Installation Guide, Rev. E  
• Ground yourself to the drive whenever the drive elec-  
tronics are or will be exposed. Connect yourself to  
ground with a wrist strap (Seagate part number  
12263496). Connection may be made to any grounded  
metal assembly. As a general rule, remember that you  
and the drive electronics must all be grounded to avoid  
potentially damaging static discharges.  
• Turn off the power before removing or installing the DC  
power cable.  
• Do not remove any circuit boards from the drive.  
• Never use an ohmmeter on any circuit boards.  
• When installing the drive on a carrier or tray, discharge  
the static electricity from the carrier or tray prior to  
inserting it into the system.  
Important safety information and precautions  
Caution. Use forced-air ventilation when bench-testing  
the drive to ensure proper cooling of drive  
components.  
Usepropersafetyandrepairtechniquesforsafe, reliable  
operation of this unit. Service should be done only by  
qualifiedpersons. Werecommendtheproceduresinthis  
manual as effective ways of servicing the unit. Some  
procedures require the use of special tools. For proper  
maintenance and safety, you must use these tools as  
recommended.  
 
Barracuda 2LP Installation Guide, Rev. E  
3
The procedures in this manual and labels on the unit  
contain warnings and cautions that must be carefully  
read and followed to minimize or eliminate the risk of  
personal injury. The warnings point out conditions or  
practices that may endanger you or others. The cautions  
point out conditions or practices that may damage the  
unit, possibly making it unsafe for use.  
These warnings and cautions are not exhaustive. We  
cannot possibly know, evaluate, and advise you of all the  
ways in which maintenance might be performed or the  
possible risk of each technique. Consequently, we have  
not completed any such broad evaluation. If you use a  
non-approved procedure or tool, first ensure that the  
method you choose will not risk either your safety or unit  
performance.  
Always observe the following warnings and precautions:  
• Performallmaintenancebyfollowingtheproceduresin  
this manual.  
• Follow all cautions and warnings in the procedures.  
• Usesoundsafetypracticeswhenoperatingorrepairing  
the unit.  
• Use caution when troubleshooting a unit that has  
voltages present. Turn off power to the unit before  
servicing it.  
• Wear safety shoes when removing or replacing heavy  
parts.  
 
4
Barracuda 2LP Installation Guide, Rev. E  
• Ensure that the internal temperature of the rack or  
cabinet does not exceed the limits defined for the drive  
when the drive is mounted in an equipment rack or  
cabinet. When units are stacked vertically, pay special  
attention to the top where temperatures are usually  
highest.  
• Follow the precautions listed above in “Electrostatic  
discharge protection.”  
• Do not remove any circuit boards from the drive chas-  
sis. Return the entire drive for depot repair if any circuit  
boardisdefective.Removalofcircuitboardsbyperson-  
nel not performing depot repair will damage compo-  
nents and may void the warranty.  
• Donotremovetheheadanddiscassembly(HDA)from  
thedrivechassis.Returntheentiredrivefordepotrepair  
if the HDA is defective.  
• Do not attempt to disassemble the HDA. It is not field  
repairable. If the sealed HDA is opened by personnel  
not performing depot repair, this will damage compo-  
nents and void the warranty.  
Asacomponent,thisdriveisdesignedtobeinstalledand  
operatedinaccordancewithUL1950,IEC950,EN60950,  
CSA C22.2 950, and VDE0805.  
Seagate takes all reasonable steps to ensure that its  
products are certifiable to currently accepted standards.  
 
Barracuda 2LP Installation Guide, Rev. E  
5
Typical applications of these disc drives include cus-  
tomer packaging and subsystem design. Safety agen-  
ciesconditionallycertifycomponentassemblies,suchas  
the Barracuda disc drive, based on their final acceptabil-  
ity in the end-use product. The subsystem designers are  
responsible for meeting these conditions of acceptability  
in obtaining safety/regulatory agency complianceintheir  
end-use products and for certifying where required by  
law. A necessary part of meeting safety requirements is  
the provision for overcurrent protection on drive SELV  
supply voltages.  
This unit is a component part and as such is not meant to  
comply with FCC or similar national requirements as a  
stand-alone unit. Engineering radiated emissions test  
results are available through the Seagate Safety Depart-  
ment to assist the subsystem designer.  
Wichtige Sicherheitshinweise  
Vorsicht.Beim Testen des Laufwerks auf dem Prüftisch  
ist Fremdbelüftung vorzusehen, um eine ausreichende  
Kühlung der Laufwerkkomponenten sicherzustellen.  
Verwenden Sie geeignete Sicherheits- und  
Reparaturverfahren, um den sicheren, zuverlässigen  
Betrieb dieser Einheit zu gewährleisten. Reparaturen  
dürfennurvonqualifiziertemFachpersonalvorgenommen  
 
6
Barracuda 2LP Installation Guide, Rev. E  
werden.WirempfehlendieVerfahrenindiesemHandbuch  
als effektive Methoden zur Wartung und Reparatur der  
Einheit. Einige Verfahren erfordern Spezialwerkzeuge;  
diese müssen zur sachgemäßen Ausführung der  
Wartungsarbeiten und aus Sicherheitsgründen den  
Empfehlungen entsprechend verwendet werden.  
DieVerfahrenindiesemHandbuchunddieAufkleberauf  
demGerätenthaltenWarn-undVorsichtshinweise.Diese  
Hinweise sind sorgfältig durchzulesen und zu beachten,  
um das Risiko von Verletzungen auf ein Mindestmaß zu  
beschränkenoderganzzuvermeiden.DieWarnhinweise  
machenaufSituationenoderPraktikenaufmerksam, die  
Sie oder andere gefährden könnten. Die  
VorsichtshinweisemachenaufSituationenoderPraktiken  
aufmerksam, die die Einheit beschädigen können, so  
daß deren Gebrauch mit Risiko behaftet ist.  
Die Warn- und Vorsichtshinweise sind nicht  
allumfassend! Es ist uns einfach nicht möglich, alle  
Wartungsmethoden oder die eventuellen Risiken jeder  
Methode zu kennen, zu beurteilen und Sie  
entsprechend zu beraten. Aus diesem Grund haben  
wir auf eine derartige umfassende Beurteilung  
verzichtet. Falls Sie ein hier nicht beschriebenes  
Verfahren oder Werkzeug verwenden, stellen Sie  
zuerst sicher, daß das gewählte Verfahren weder Ihre  
 
Barracuda 2LP Installation Guide, Rev. E  
7
persönliche Sicherheit noch die Leistung der Einheit  
gefährdet.  
Beachten Sie in jedem Fall die folgenden Warn-und  
Vorsichtshinweise:  
• Führen Sie alle Wartungsarbeiten entsprechend den  
Anweisungen in diesem Handbuch aus.  
• Beachten Sie alle Warn- und Vorsichtshinweise in  
diesem Handbuch.  
• Treffen Sie beim Betrieb oder bei der Reparatur der  
Einheit angemessene Sicherheitsvorkehrungen.  
• WenneineEinheitunterSpannungsteht,gehenSiebei  
derFehlerdiagnosebesondersvorsichtigvor.Schalten  
SiedieEinheitaus,bevorSiemitdenReparaturarbeiten  
beginnen.  
• TragenSieSicherheitsschuhe,wennSieschwereTeile  
aus- bzw. einbauen.  
• Wenn das Laufwerk in einem Einbaugestell oder  
Gehäuse montiert ist, sorgen Sie dafür, daß die  
Temperatur im Inneren des Gestells oder Gehäuses  
die für das Laufwerk vorgegebenen Grenzwerte nicht  
übersteigt. Wenn Einheiten vertikal übereinander  
betestigtwerden,achtenSiebesondersaufdenoberen  
Stapelbereich, da dort die Temperatur gewöhnlich am  
höchsten ist.  
 
8
Barracuda 2LP Installation Guide, Rev. E  
• Befolgen Sie die oben unter “Electrostatic Discharge  
Protection” angegebenen Sicherheitsmaßnahmen.  
• NehmenSiekeinePlatinenausdemLaufwerkgehäuse.  
WenneinePlatinedefektist,mußdasgesamteLaufwerk  
zurReparatureingeschickt werden.DieHerausnahme  
von Platinen durch anderePersonen als die für die  
werkseitige Reparatur zuständigen kann zu einer  
Beschädigung der Komponenten und Erlöschen des  
Garantieanspruchs führen.  
• Die vormontierte Kopf- und Festplatteneinheit (HDA)  
nicht aus dem Laufwerkgehäuse nehmen! Falls die  
HDA beschädigt ist, schicken Sie das gesamte  
Laufwerk zur Reparatur ein.  
• Die HDA ist nicht vor Ort reparierbar und darf nicht  
auseinandergenommen werden! Öffnen der  
versiegeltenHDAdurchanderePersonenalsdiefürdie  
werkseitige Reparatur zuständigen hat eine  
Beschädigung der Komponenten und Erlöschen des  
Garantieanspruchs zur Folge.  
Als Teilkomponente ist dieses Laufwerk für die Installa-  
tion und den Betrieb in Übereinstimmung mit UL 1950,  
IEC950, EN60950, CSA C22.2 950 und VDE0805  
vorgesehen.  
Seagateistständigbemüht,dieZulassungsfähigkeitvon  
Seagate-Produkten im Rahmen der gegenwärtig  
 
Barracuda 2LP Installation Guide, Rev. E  
9
geltendenStandardszugewährleisten.Zudentypischen  
Anwendungen dieser Festplattenwerke zählen  
Systemeinbau durch den Kunden und die Konstruktion  
vonUntersystemen.Sicherheitsbehördengewähreneine  
bedingte Zulassung für Komponenten wie das Barra-  
cuda-Festplattenlaufwerk vorbehaltlich der endgültigen  
ZulasssungimEndprodukt.DesignervonUntersystemen  
sind dafür verantwortlich, die Voraussetzungen für die  
Einhaltung sicherheits- oder aufsichtsbehördlicher  
Vorschriften in ihren Endprodukten und - falls gesetzlich  
vorgeschrieben - für die Zulassung zu schaffen.  
Eine Grundvoraussetzung zur Einhaltung der  
Sicherheitsanforderungen ist die Bereitstellung  
eines  
Überlastschutzes  
für  
die  
SELV-  
Versorgungsspannungen des Laufwerks.  
DiesesGerätisteineBaugruppeundunterliegtalssolche  
nicht den Anforderungen der FCC oder ähnlicher  
nationaler Behörden für eigenständige Geräte.  
Technische Testergebnisse zu elektromagnetische  
Strahlung sind für Designer von Untersystemen auf  
AnfragevonderSeagate-Sicherheitsabteilungerhältlich.  
 
10  
Barracuda 2LP Installation Guide, Rev. E  
Technical support services  
Seagate Technology provides technical support litera-  
ture and diagnostic utilities to authorized distributors.  
Please contact your dealer for technical support and  
installation troubleshooting. Product technical support is  
availableforallSeagateproductsbycallingtheSeaFAX™,  
SeaFONE™, SeaTDD™, or SeaBOARD™ services.  
Thesearetollcallsifyoudialfromoutsideofthenumber’s  
local dialing area.  
SeaFAX:  
USA (408) 438-2620; England 44-62-847-7080  
Use a touch-tone telephone to access Seagate’s auto-  
matedFAXsystemandselecttechnicalsupportinforma-  
tion by return FAX. This service is available 24 hours a  
day, 7 days a week.  
CompuServe Forum  
Online support for Seagate products is available on  
CompuServe. This includes an extensive question and  
answermessagebase,downloadableutilities,anddocu-  
mentation files in Adobe™ Acrobat™ format which you  
can download and view from your own computer. Type  
“Go Seagate” from within CompuServe to access this  
service.  
 
Barracuda 2LP Installation Guide, Rev. E  
11  
SeaFONE: (408) 438-8222  
Technicalsupportspecialistsareavailablefrom8:00A.M.  
to 5:00 P.M. PST, Monday through Friday. Recorded  
technical information on selected Seagate products is  
provided while you are on hold. Recordings are acces-  
sible 24 hours a day, 7 days a week.  
SeaTDD: (408) 438-5382  
TDD is a telecommunication device for the deaf where  
two people can communicate using a keyboard con-  
nected to the phone line. A TDD device is required to  
access this service, which is available from 8:00 A.M. to  
5:00 P.M. PST, Monday through Friday.  
SeaBOARD:  
The Seagate Technical Support Bulletin Board System  
(BBS) is available 24 hours a day, 7 days a week. A  
modem is required to access this service. The communi-  
cations software must be set for eight data bits, no parity,  
and one stop bit (8N1). These operate at 300 to 9600  
baud. With this service you can access:  
• Specifications and jumper configurations  
• Reprints of Seagate documentation  
• Utilities that you can download to your own computer  
 
12  
Barracuda 2LP Installation Guide, Rev. E  
Location  
Modem number  
USA, Mexico, Latin America  
England  
Germany  
Singapore  
Australia  
Canada  
(408) 438-8771  
44-62-847-8011  
49-89-140-9331  
65-292-6973  
61-2-756-2359  
(416) 856-5581  
33-1-40-67-1034  
82-2-556-7294  
France  
Korea  
 
Barracuda 2LP Installation Guide, Rev. E  
13  
General description  
Barracuda 2LP SCSI disc drives are high-speed, ran-  
dom-access digital-data storage devices.  
The drive is a component for installation in an enclosure  
designed for the drive. This is often a rack within the  
system or an external enclosure designed to house one  
or more disc drives or other peripheral units. In either  
case, the disc drive must receive adequate cooling (refer  
to “Providing adequate cooling”) and it must be suffi-  
ciently grounded and shielded from emissions. TheBar-  
racuda 2LP Product Manual (part number 83328930)  
contains guidelines for a properly designed enclosure.  
SCSI I/O  
Connector  
DC Power Connector  
Figure 1. Barracuda 2LP disc drive (N/ND model shown)  
 
14  
Barracuda 2LP Installation Guide, Rev. E  
Characteristics  
ST31250  
ST32550  
Interface  
Fast SCSI-21  
Fast SCSI-21  
Capacity  
Unformatted  
1,205.3 Mbytes 2,541.3 Mbytes  
1,020.9 Mbytes 2,147.4 Mbytes  
Formatted2  
Recording  
Cylinders (user)  
Read/write data heads 5  
3,711  
3,510  
11  
Servo heads  
1
1
Avg bytes/track  
64,160  
64,160  
Seek time3  
Average read  
Average write  
8.0 msec  
9.0 msec  
8.0 msec  
9.0 msec  
Disc rotation  
RPM  
7,200  
7,200  
Average latency  
4.17 msec  
4.17 msec  
Internal transfer rate  
(Mbits/sec)  
47.5 to 72.0  
49.4 to 72.0  
Max sync. SCSI transfer rate  
N/ND  
W/WD/WC/DC  
10 Mbytes/sec  
20 Mbytes/sec  
10 Mbytes/sec  
20 Mbytes/sec  
Multi-segmented cache 512 Kbytes  
512 Kbytes  
 
Barracuda 2LP Installation Guide, Rev. E  
15  
1Can also be operated according to SCSI-1 protocol.  
2Standard factory units are formatted as follows:  
512 data bytes per sector  
9 spare sectors per cylinder  
1 cylinder at the innter track reserved for spares  
3Not including on-board controller overhead.  
 
16  
Barracuda 2LP Installation Guide, Rev. E  
DC power requirements  
Single-ended Differential  
+5V11 +12V  
+5V11 +12V  
Voltage regulation5  
± 5% ± 5%2 ± 5% ± 5%2  
Amps  
Maximum operating current1 0.93  
Maximum starting current  
0.6  
1.17  
0.6  
Peak DC3, 6  
Peak AC3  
0.93  
1.35  
1.93  
1.00  
1.35  
1.93  
Delayed motor start (max)1,4 0.88  
0.12  
0.92  
0.12  
Peak operating current  
Typ DC1, 10  
Max DC1  
Max (peak)  
0.91  
0.93  
1.00  
0.57  
0.60  
1.56  
1.13  
1.17  
1.95  
0.57  
0.60  
1.56  
Track following (DC)  
at OD1  
0.91  
0.88  
0.5  
0.51  
0.99  
0.96  
0.50  
0.51  
at ID1  
Read track  
OD DC1, 14  
AC  
0.96  
1.03  
0.53  
0.73  
1.35  
1.95  
0.53  
0.73  
Seeking  
Typical DC1, 13  
Maximum DC1  
Maximum (peak) AC  
0.89  
0.92  
0.95  
0.78  
0.82  
1.60  
0.99  
1.10  
1.67  
0.78  
0.82  
1.60  
 
Barracuda 2LP Installation Guide, Rev. E  
17  
1
Measured with an average reading DC ammeter. Instanta-  
neous +12V current peaks will exceed these values.  
2
A 10% tolerance is permissible during initial start of the  
spindle but must return to±5% before reaching 7,200 RPM.  
The ±5% must be maintained after the drive signifies that its  
power-up sequence has been completed and that the drive  
is able to accept selection by the host initiator.  
3 See the +12V current profile in the Barracuda 2LP Product  
Manual (publication number 83328930).  
4 This condition occurs when the Motor Start option is enabled  
and the drive has not yet received a Start Motor command.  
5 See “Conducted noise immunity” in the Barracuda 2LP  
Product Manual.The specified voltage tolerance is inclusive  
of ripple, noise, and transient response.  
6 At power-up, the motor current regulator limits the +12V  
current to an average value of less than 1.4A, although  
instantaneous peaks may exceed this value. These peaks  
should measure 5 msec duration or less.  
7 Minimum current loading for each supply voltage is not less  
than 4% of the maximum operating current shown.  
8 Use separate ground returns for +5 and +12V supplies.  
9 Where power is provided to multiple drives from a common  
supply, carefully consider individual-drive power require-  
ments. Wheremultipleunitsarepoweredonsimultaneously,  
be sure the peak starting current is available to each device.  
10 Operating condition is a third-stroke seek at OD and read  
one Track. The command is issued every 0.075 seconds  
(every 0.063 seconds on wide and SCA drives).  
 
18  
Barracuda 2LP Installation Guide, Rev. E  
11 No terminator power. See Section 11.7.3.4 in the Barra-  
cuda 2LP Product Manual.  
12 All power-saving features are enabled (ASA II code only).  
13 Seeking is defined as a third-stroke seek at OD. The com-  
mand is issued every 20 msec.  
14 Read track is defined as repeat reads of track 15 with a  
78% duty cycle on N models, 32% duty cycle on W  
models, 48% duty cycle on WC models, 60% duty cycle  
on ND models, 44% duty cycle on WD models, and 44%  
duty cycle on DC models.  
 
Barracuda 2LP Installation Guide, Rev. E  
19  
Initial setup information  
Thegeneralinformationbeginningonthispageappliesto  
all of the Barracuda 2LP drive models. After reading the  
general information topics, refer to the appropriate drive-  
specific section listed below for additional information  
about configuring and installing your particular model.  
Drive models  
Page  
ST31250N  
ST32550N  
ST31250ND  
ST32550ND  
33  
ST31250W  
ST32550W  
ST31250WD  
ST32550WD  
38  
ST31250WC  
ST32550WC  
ST31250DC  
ST32550DC  
44  
WC drives  
General information  
The following general information topics are discussed:  
• SCSI ID jumpers  
• Drive termination  
• Synchronizing spindles  
• Other applicable jumper options  
• Providing adequate cooling  
• Mounting the drive and connecting cables*  
• Formatting the drive  
 
20  
Barracuda 2LP Installation Guide, Rev. E  
*This mounting procedure does not apply to WC or DC  
model drives. To mount a WC or DC drive, plug the drive  
into the system's single connector attachment (SCA)  
position on the system's back panel.  
SCSI ID jumpers  
EachdeviceontheSCSIchainmusthaveauniqueSCSI  
ID. The host system’s SCSI controller usually uses the  
highest-numberedIDavailable;thereforethelower-num-  
bered SCSI IDs are normally used for the other SCSI  
devices such as this Barracuda disc drive.  
Note. Most SCSI controllers (host adapters) allow you to  
skip a SCSI ID. For example, you can have ID0,  
ID1, and ID3 (skipping ID2). Other controllers do  
not allow this so be sure to refer to your system or  
controller user’s manual for details about its re-  
quirements for proper SCSI device installation.  
Most Barracuda disc drives are factory set with the SCSI  
ID set at 0. To change the SCSI ID, refer to the appropri-  
ate drive section for your model.  
If, after completing the installation process, the drive’s  
LED does not show on/off activity when the host is trying  
to communicate with the drive, a duplicate SCSI ID may  
be the problem. If this is the case, change the ID so that  
each device on the SCSI chain has its own unique ID.  
 
Barracuda 2LP Installation Guide, Rev. E  
21  
Also check your system or controller user’s manual to  
ensure that you have not violated its SCSI ID numbering  
recommendations.  
Drive termination  
IfyouareinstallingaBarracuda2LPdriveinasystemthat  
has other SCSI devices installed, terminate only the end  
devices on the SCSI chain. A SCSI “device” is any disc  
drive, scanner, tape-backup unit, or other piece of hard-  
ware connected to your system using the SCSI bus.  
The top example in Figure 2 shows an internal hard disc  
at one end of the SCSI bus with the SCSI controller at the  
other end (both are terminated). The bottom example  
shows two additional SCSI devices connected exter-  
nally—this means the SCSI controller is no longer on the  
end of the SCSI chain and should not be terminated.  
Internal SCSI cable  
Internal  
Internal  
Controller  
SCSI device SCSI device  
Terminate  
Internal SCSI cable  
External  
SCSI  
cable  
Internal  
Internal  
SCSI device SCSI device  
External  
External  
Controller  
SCSI device SCSI device  
Terminate  
Figure 2. SCSI bus termination  
 
22  
Barracuda 2LP Installation Guide, Rev. E  
For information about how to terminate your drive, refer  
to the appropriate drive-specific section.  
Terminator power  
You usually will not need to change this option and can  
normally leave the drive configured as it was shipped  
fromthefactory.Forinformationabouthowtochangethe  
terminator power option on your drive, refer to the appro-  
priate drive-specific section.  
Synchronizing spindles  
If you are installing two or more Barracuda drives, you  
may(optionally) synchronizetheirspindlestoreducethe  
latency associated with switching from one drive to  
another. Spindle sync cables are used to connect the  
drives.  
After connecting each drive with spindle sync cables,  
designate a master spindle sync reference source. This  
master source is normally a disc drive located on the  
same SCSI bus as the other drives you want to synchro-  
nize with. To designate a drive as the master, use SCSI  
interface commands. Refer to the product manual for  
information about using these commands.  
Forinformationabouthowtosynchronizethespindlesfor  
your drive, refer to the appropriate drive-specific section.  
 
Barracuda 2LP Installation Guide, Rev. E  
23  
Providing adequate cooling  
Theenclosuredesignmustensureadequate coolingfor  
the drive. The maximum ambient temperature is 50oC.  
The drive’s product manual (83328930) describes how  
to evaluate the air-flow design.The evaluation consists  
ofensuring that thecasetemperaturesofcertain critical  
componentsremainwithinacceptablelimitsduringdrive  
operation.  
We recommend orienting the drive or directing the air  
flow in a way that creates the least amount of air-flow  
resistance while providing air flow above the circuit  
boards and around the head and disc assembly (HDA).  
Also, choose the shortest possible path between the air  
inlet andexit.Thisminimizesthe distancetraveledbyair  
that is heated by the drive and by other nearby heat  
sources.  
Figure3showstwodesignapproacheswithoneormore  
fans used to generate air flow.The air-flow patterns can  
be created by thefanseither pushing or drawing air.The  
overall flow pattern can be directed from front to back,  
back to front, or side to side.  
 
24  
Barracuda 2LP Installation Guide, Rev. E  
Kühlung des Systems  
Die Gehäusekonstruktion muß eine ausreichende  
Kühlung des Laufwerkes gewährleisten. Die  
Umgebungstemperatur darf maximal 50oC betragen.  
Die Produkthandbuch Barracuda 2LP (Dokument  
83328930) enthalten Anweisungen zur Beurteilung der  
Luftstromkonstruktion.DieBeurteilungmußsicherstellen,  
daß sich die Gehäusetemperatur bestimmter kritischer  
Komponenten bei Laufwerkbetrieb innerhalb  
zugelassener Grenzen hält.  
Wir empfehlen, das Laufwerk so zu orientieren oder den  
Luftstrom so zu lenken, daß der geringste  
Luftstromwiderstand erzeugt wird und gleichzeitig ein  
Luftstrom über den Platinen und um die Kopf- und  
Festplatteneinheit (HDA) gegeben ist. Wählen Sie einen  
möglichst kurzen Weg zwischen Lufteinlaß und -auslaß.  
Dadurch wird die Strecke, die die vom Laufwerk und  
anderen nahegelegenen Hitzequellen aufgewärmte Luft  
zurücklegt, auf ein Minimum beschränkt.  
Abbildung 3 zeigt zwei Konstruktionsmöglichkeiten, bei  
denen ein oder mehrere Lüfter den Luftstrom erzeugen.  
Der Luftstromverlauf wird durch die Lüfter gesteuert, die  
entweder Luft einblasen oder abziehen. Generell kann  
der Luftstrom entweder von vorne nach hinten oder von  
hinten nach vorne verlaufen.  
 
Barracuda 2LP Installation Guide, Rev. E  
25  
Above unit  
Über der Einheit  
Note. Air flows in the direction shown (back to front)  
or in reverse direction (front to back)  
Under unit  
Unter der Einheit  
Hinweis. Luftstrom in der angezeigten Richtung  
(von vorne nach hinten) oder in umgekehrter  
Richtung (von hinten nach vorne)  
Above unit  
Über der Einheit  
Note. Air flows in the direction shown or  
in reverse direction (side to side)  
Under unit  
Unter der Einheit  
Hinweis. Luftstrom in der angezeigten Richtung oder in  
umgekehrter Richtung (von Seite zu Seite)  
Figure 3. Suggested air flow  
Abbildung 3. Empfohlener Luftstromverlauf  
 
26  
Barracuda 2LP Installation Guide, Rev. E  
Mounting the drive and connecting cables  
Do not touch the connector pins or any components on  
thecontrolboardwithoutobservingstatic-dischargepre-  
cautions. Always handle the drive by the frame only.  
The drive may be mounted in any orientation (horizon-  
tally, vertically, and any combination thereof); however,  
youmustensurethatthedrivereceivesadequateairflow  
for cooling.  
1. Mountthedrivetothehostsystem’schassisusingfour  
6-32 UNC screws. Two mounting holes are in each  
side of the drive and there are four mounting holes in  
the bottom of the drive.  
The maximum length that the screws should extend  
into the chassis mounting holes is 0.15 inch (3.81  
mm), measuredfromtheoutersurfaceofthechassis.  
Tighten the screws down evenly. Do not over-tighten  
orforcethescrewifitdoesnotseemtoscrewineasily,  
because this means the threads are not properly  
aligned. In this case, back the screw out and try again.  
 
Barracuda 2LP Installation Guide, Rev. E  
27  
Installation des Laufwerkes  
und Anschluß der Kabel  
Beachten Sie beim Handhaben und Anfassen der  
Anschlußstifte und Komponenten die  
Vorsichtsmaßnahmen zur Verhinderung statischer  
Aufladung. Fassen Sie das Laufwerk nur am Rahmen an.  
DasLaufwerkkanninbeliebigerOrientierung(horizontal,  
vertikaloderschräg)installiertwerden;jedochmußdafür  
gesorgt werden, daß ein ausreichender Luftstrom zur  
Kühlung des Laufwerkes vorhanden ist.  
1. Befestigen Sie das Laufwerk mit vier 6-32-UNC-  
SchraubenamGehäusedesHost-Systems.Diebeiden  
Seiten des Laufwerkes sind mit jeweils zwei  
Befestigungslöchern versehen, die Unterseite des  
LaufwerkesweistvierweitereBefestigungslöcherauf.  
GemessenvonderAußenflächedesGehäusesdürfen  
die Schrauben maximal 3,81 mm in die  
Befestigungslöcher des Gehüuses hineinragen. Die  
Schrauben müssen gleichmäßig, jedoch nicht zu fest,  
angezogen werden. Wenn sich eine Schraube nicht  
ohneWiderstandeinschraubenläßt,sinddieGewinde  
nicht korrekt aneinander ausgerichtet. In diesem Fall  
die Schraube nicht in das Gewindeloch forcieren,  
sondern die Schraube herausnehmen und erneut in  
das Gewindeloch einführen.  
 
28  
Barracuda 2LP Installation Guide, Rev. E  
2. Verify that all connections between the drive and the  
host system are correctly installed.  
2. Prüfen Sie, ob alle Verbindungen zwischen dem  
Laufwerk und dem Host-System korrekt hergestellt  
sind.  
3. Verify that you have correctly installed jumpers.  
3. StellenSiesicher,daßdieKennungsbrückeninstalliert  
sind.  
4. Connect the 50-pin SCSI cable into the drive’s SCSI  
connector(shownearlierinFigure1). Takecarenotto  
stretch or crimp this cable, and do not block the  
system’s cooling air flow with the cable.  
The drive receives DC power through a 4-pin connec-  
tormountednexttotheSCSIconnector. Theoutputof  
a power supply must meet SELV (safety extra low  
voltage) as defined in IEC 950. Figure 4 provides the  
pin information for the DC power connector. To con-  
nect the DC power cable to the drive, insert the cable  
end into the drive’s DC power connector.  
4. SchließenSiedas50-poligeSCSI-KabelandenSCSI-  
Steckverbinder des Laufwerkes an (wie bereits in  
Abbildung 1 gezeigt). Das Kabel darf nicht gedehnt  
oder gedrückt werden und es darf den Luftstrom zur  
Kühlung des Systems nicht behindern.  
 
Barracuda 2LP Installation Guide, Rev. E  
29  
Das Laufwerk wird über einen 4-poligen, neben dem  
SCSI-Anschluß befestigten Steckverbinder mit  
Gleichstrom versorgt. Der Ausgang eines Netzteils  
muß SELV (safety extra low voltage) nach IEC 950  
entsprechen. Abbildung 4 zeigt die Steckerbelegung  
für den Gleichstromanschluß. Zum Anschluß des  
GleichstromkabelsandasLaufwerkdasKabelendein  
den Gleichstromanschluß des Laufwerkes stecken.  
Pin  
1
Power  
Pin Gleichstrom  
+12V  
1
2
3
4
+12 V  
2
+12V return  
+ 5V return  
+ 5V  
+12 V Rückleitung  
+ 5 V Rückleitung  
+ 5 V  
3
4
4
3
2
1
Figure 4. DC power connector  
Abbildung 4. Gleichstromanschluß  
 
30  
Barracuda 2LP Installation Guide, Rev. E  
Note. Signal ground on the power control board (PCB)  
and the head and disc assembly (HDA) are con-  
nected together in this drive and you cannot sepa-  
rate them. The equipment in which you have  
mountedthedriveisconnecteddirectlytotheHDA  
andPCBwithoutelectricallyisolatingshockmounts.  
Maximizing the conductive contact area between  
HDA ground and system ground may reduce radi-  
ated emissions. If you do not want the system  
chassis to be connected to the HDA/PCB ground,  
you must provide a nonconductive (electrically  
isolating) method of mounting the drive in the host  
system.Thismayincreaseradiatedemissionsand  
is the system designer’s responsibility.  
Hinweis:  
DieSignalerdeaufderStromregelungskarte(PCB)  
undderKopf-undFestplatteneinheit(HDA)sindin  
diesem Laufwerk miteinander verbunden und  
können nicht getrennt werden. Das Gerät, in das  
Sie das Laufwerk eingebaut haben, ist ohne  
elektrisch isolierende Stoßdämpfer direkt an die  
HDA und PCB angeschlossen. Die  
elektromagnetische Strahlung kann reduziert  
werden, indem Sie eine möglichst große leitende  
Kontakfläche zwischen der HDA-Erdung und der  
Systemerdung vorsehen. Wenn Sie das  
 
Barracuda 2LP Installation Guide, Rev. E  
31  
Systemgehäuse nicht an die HDA/PCB-Erdung  
anschließen wollen, müssen Sie das Laufwerk auf  
nichtleitende Weise (galvanisch isoliert) im Host-  
System einbauen. Die daraus u.U. resultierende  
verstärkte elektromagnetische Strahlung fällt in  
den Zuständigkeitsbereich des Systemdesigners.  
5. Replace the host system’s cover.  
5. Setzen Sie das Gehäuseoberteil des Host-Systems  
wieder auf.  
Formatting the drive  
Warning. Formatting a drive erases all user data. Be  
sure that you understand this principle before  
formatting any hard disc drive.  
It is not necessary to format a drive which has  
previously been used to store data, unless  
your intention is to erase all user data.  
1. Turn on DC power.  
2. Boot the system from a system floppy disc or from a  
previously installed hard disc drive if there is one.  
3. Format the disc drive.The Barracuda 2LP disc drive  
is designed to operate with a variety of operating  
systems; therefore, please refer to your system or  
SCSI controller manual forinformationabout format-  
ting and setting up the drive.  
 
32  
Barracuda 2LP Installation Guide, Rev. E  
Enabling write cache  
Write caching is a feature that allows the drive to transfer  
write data to its own cache, tell the controller that the task  
iscomplete,andthenactuallycompletethewriteatalater  
time. This improves write performance by freeing the  
CPU to go on to its next command.  
Warning. Information can be lost is you enable write  
cache and there is a system failure (for ex-  
ample, power failure) before the data has  
actually been physically written to the disc.  
OEM drives are shipped with write cache disabled by  
default.Ifyouwanttoenablethewritecache,refertoyour  
system’s drive controller and software utility documenta-  
tion. Seagate provides an ASPI utility that you can use in  
a PC compatible system to enable the write cache. It is  
available on Seagate’s CompuServe forum and on the  
Seagate BBS (refer to “Technical support services” on  
page 9).  
 
Barracuda 2LP Installation Guide, Rev. E  
33  
N/ND drives  
Setting the SCSI ID jumpers  
Use the J4 connector to set the SCSI ID (see Figure 5).  
TochangetheSCSIID,installjumpersontheappropriate  
pins as shown in the illustration.  
J4  
(front view of J4)  
Pin 1  
J4  
Pin 2  
Pin 1  
SCSI ID = 0 (default)  
SCSI ID = 1  
SCSI ID = 2  
SCSI ID = 3  
SCSI ID = 4  
SCSI ID = 5  
SCSI ID = 6  
SCSI ID = 7  
Figure 5. Setting the SCSI ID  
 
34  
Barracuda 2LP Installation Guide, Rev. E  
N/ND drives  
Terminating the drive  
ST31250N and ST32550N drives are terminated with  
permanently mounted IC active terminators. If you install  
one of thesedrives and it is not on the end of the SCSI  
bus, disabletheterminatorsbyremovingthejumperfrom  
pins 5 and 6 of connector J1 (see Figure 6). If you install  
the drive on the end of the SCSI bus, enable termination  
by installing a jumper on pins 5 and 6 of connector J1.  
Note. Use active terminators when terminating the bus.  
ST31250NDandST32550NDdrivesdonothaveinternal  
terminators or any other way of adding internal termina-  
tion to the drive. You must provide external active termi-  
nation (ANSI SCSI-2 Alternative 2) to these drives when  
termination is required.  
J1  
Pin 6  
Pin 1  
J2  
Pin 1  
Pin 1  
Pin 2  
J1  
Pin 6  
Enable SCSI  
terminator (default)  
Disable SCSI  
terminator  
Figure 6. Terminating the drive  
 
Barracuda 2LP Installation Guide, Rev. E  
35  
N/ND drives  
Terminator power  
There are four possible terminator power configurations  
for ST31250N and ST32550Ndrives (see Figure 7). You  
willnotnormallyneedtochangethisoptionandcanleave  
the drive configured as it was shipped from the factory.  
ST31250ND and ST32550ND drives should be config-  
ured with a jumper connecting J1 pins 1 and 3 (and no  
jumper on J1 pins 2 and 4) as illustrated in Figure 7.  
ST31250N and ST32550N  
J1 Connector  
Pin 6  
Pin 1  
ST31250ND and  
ST32550ND  
J1 Connector  
Pin 1  
Pin 2  
Pin 1  
J1  
Pin 6  
ST31250N and ST32550N  
Pin 2  
Term. power from drive (default)  
Term. power to SCSI bus  
Term. power from SCSI bus  
Term. power to SCSI bus  
and drive  
Pin 1  
Pin 2  
J1  
ST31250ND and ST32550ND  
Term. power to SCSI bus (default)  
Figure 7. Setting terminator power jumpers  
 
36  
Barracuda 2LP Installation Guide, Rev. E  
N/ND drives  
Synchronizing spindles  
Usepins5and6ontheJ4connectortoattachthespindle  
sync cable. See Figure 8.  
Pin 1  
J2  
J4  
(front view of J4)  
Pin 1  
J4  
Pin 2  
Pin 1  
Spindle sync  
cable connector  
Spindle Sync Reference  
Spindle Sync Ground  
Figure 8. Spindle sync connectors  
 
Barracuda 2LP Installation Guide, Rev. E  
37  
N/ND drives  
Other applicable jumper options  
Several other jumper options are available as illustrated.  
J2  
Pin 2  
Pin 1  
Reserved  
Parity Check option  
Pin 1  
J2  
Enable parity check of  
SCSI bus (default).  
Disable parity check.  
Write Protect option  
Write protect = Off  
(enables writing –  
default)  
Write protect = On  
(disables writing)  
J4  
Motor Start option  
(front view of J4)  
Pin 1  
J4  
Pin 2  
Pin 1  
Enable motor start. The  
drive waits for the Start  
Unit command from the  
host before starting the  
spindle motor.  
Reserved  
Disable motor start  
Remote LED  
connector*  
GND (cathode)  
POS (anode)  
(default). The drive  
starts according to the  
Delay Motor Start option.  
*Note to subsystem designers: In  
Europe, a red LED indicates an error  
or warning condition. For this reason,  
you may want to use a color other  
than red with this connection.  
Delay Motor Start  
option (valid only if the  
Motor Start jumper is  
not connected)  
Disable the Delay Motor  
Start option (default).  
Motor start delay equal  
to the SCSI ID multiplied  
by 10 seconds. For  
example, if the SCSI  
ID = 2, the drive starts  
in 20 seconds.  
Figure 9. Additional jumper options  
 
38  
Barracuda 2LP Installation Guide, Rev. E  
W/WD drives  
Setting the SCSI ID jumpers  
Use the J5 connector to set the SCSI ID (Figure 10). To  
change the SCSI ID, install jumpers on the appropriate  
pins as shown in the illustration.  
SCSI I/O  
Connector  
DC Power  
Connector  
Pin 1  
Pin 1  
J5  
4P  
3P 2P  
1P  
ID3 ID1  
ID2 ID0  
J5  
SCSI ID = 0 (default)  
SCSI ID = 1  
SCSI ID = 2  
SCSI ID = 3  
SCSI ID = 4  
SCSI ID = 5  
SCSI ID = 6  
SCSI ID = 7  
SCSI ID = 8  
SCSI ID = 9  
SCSI ID = 10  
SCSI ID = 11  
SCSI ID = 12  
SCSI ID = 13  
SCSI ID = 14  
SCSI ID = 15  
Figure 10. Setting the SCSI ID  
 
Barracuda 2LP Installation Guide, Rev. E  
39  
W/WD drives  
Terminating the drive  
ST31250W and ST32550W drives are terminated with  
permanently mounted IC active terminators. If you install  
one of these drives and it is not on the end of the SCSI  
bus,disabletheterminatorsbyremovingthejumperfrom  
pins 5 and 6 of connector J1. If you install the drive on the  
end of the SCSI bus, enable termination by installing a  
jumper on pins 5 and 6 of connector J1 (see Figure 11).  
Note. Use active terminators when terminating the bus.  
ST31250WD and ST32550WD drives do not have inter-  
nal terminators or any other way of adding internal  
terminationtothedrive.Youmustprovideexternalactive  
termination (ANSI SCSI-2 Alternative 2) to these drives  
when termination is required.  
J1  
Pin 1  
J2  
Pin 1  
Pin 1  
Pin 2  
J1  
Enable SCSI  
terminator (default)  
Disable SCSI  
terminator  
Figure 11. Terminating the drive (ST32550W shown)  
 
40  
Barracuda 2LP Installation Guide, Rev. E  
W/WD drives  
Terminator power  
There are four possible terminator power configurations  
for ST31250W and ST32550W drives (see Figure 12).  
You will not normally need to change this option and can  
leave the drive configured as it was shipped from the  
factory.  
ST31250WD and ST32550WD drives should be config-  
ured with a jumper connecting J1 pins 1 and 3 (and no  
jumper on J1 pins 2 and 4) as illustrated in Figure 12.  
ST31250W and ST32550W  
J1 Connector  
Pin 6  
ST31250WD and  
ST32550WD  
Pin 1  
Pin 2  
Pin 1  
J1 Connector  
Pin 4  
Pin 3  
Pin 1  
J1  
Pin 6  
ST31250W and ST32550W  
Pin 2  
Term. power from drive (default)  
Term. power to SCSI bus  
Term. power from SCSI bus  
Term. power to SCSI bus  
and drive  
J1  
Pin 2  
Pin 4  
Pin 3  
ST31250WD and ST32550WD Pin 1  
Term. power to SCSI bus (default)  
Figure 12. Setting terminator power jumpers  
 
Barracuda 2LP Installation Guide, Rev. E  
41  
W/WD drives  
Synchronizing spindles  
Use pins 11 and 12 on the J5 connector to attach the  
spindle sync cable. See Figure 13.  
SCSI I/O  
Connector  
DC Power  
Connector  
Pin 1  
Pin 1  
J5  
4P  
3P 2P  
1P  
SS  
J5  
Spindle Sync Reference  
Spindle Sync Ground  
Spindle sync  
cable connector  
Figure 13. Spindle sync connectors  
 
42  
Barracuda 2LP Installation Guide, Rev. E  
W/WD drives  
Other applicable jumper options  
Other option jumpers are available as illustrated below.  
Pin 1  
J2  
J2  
Pin 2  
Pin 1  
Reserved  
Parity Check option  
Enable parity check of SCSI bus (default).  
Disable parity check.  
Write Protect option  
Write protect = Off (enables writing – default)  
Write protect = On (disables writing)  
Motor Start option  
Enable motor start. The drive waits for the Start  
Unit command from the host before starting the  
spindle motor.  
Disable motor start (default). The drive starts  
according to the Delay Motor Start option.  
Delay Motor Start option (valid only if  
the Motor Start jumper is not connected)  
Disable the Delay Motor Start option (default).  
Motor start delay equal to the SCSI ID multiplied  
by 10 seconds. For example, if the SCSI ID = 2,  
the drive starts in 20 seconds.  
Figure 14a. Additional jumper options  
 
Barracuda 2LP Installation Guide, Rev. E  
43  
W/WD drives  
Pin 1  
J2  
SCSI I/O  
Connector  
Pin 1  
Pin 1  
J5  
GND (cathode)  
Remote unit active  
LED connector  
J4  
POS (anode)  
(front view of J4)  
Pin 1  
J4  
Pin 2  
Pin 1  
SCSI ID = 0  
Fault LED pin (+)  
SCSI ID = 1  
Vendor Unique  
SCSI ID = 2  
SSREF (+)  
SCSI ID = 3  
Unit Active LED pin (+)  
Enable termination  
Ground  
+5 volts  
Not connected  
Reserved  
Figure 14b. Additional jumper options  
 
44  
Barracuda 2LP Installation Guide, Rev. E  
WC/DC drives  
Setting the SCSI ID jumpers  
The SCSI ID for WC drives is normally set over the SCSI  
bus by the host system using connector contacts 39  
(ID0), 40 (ID2), 79 (ID1), and 80 (ID3). Systems design-  
ers may, optionally, install a remote operator panel con-  
nectiontosettheSCSIID.Figure15billustratestheSCSI  
ID pins used for this purpose.  
Terminating the drive  
ST31250WC and ST32550WC drives do not have inter-  
nal terminators or any other way of adding internal  
termination to the drive. You must provide single-ended  
external active termination (ANSI SCSI-2 Alternative 2)  
to these drives when termination is required.  
Synchronizing spindles  
SpindlesynchronizationforWCdrivesisnormallyhandled  
on the SCSI bus by the host system using connector  
contact 37 for the spindle sync reference signal. System  
designers may, optionally, install a spindle sync cable  
using pin 6 on the J4 connector to provide +SSREF (see  
Figure 15b).  
 
Barracuda 2LP Installation Guide, Rev. E  
45  
WC/DC drives  
Applicable jumper options  
Option jumpers are available as illustrated below.  
Pin 1  
J2  
J2  
Pin 2  
Pin 1  
Reserved  
Parity Check option  
Enable parity check of SCSI bus (default).  
Disable parity check.  
Write Protect option  
Write protect = Off (enables writing – default)  
Write protect = On (disables writing)  
Motor Start option  
Enable motor start. The drive waits for the Start  
Unit command from the host before starting the  
spindle motor.  
Disable motor start (default). The drive starts  
according to the Delay Motor Start option.  
Delay Motor Start option (valid only if  
the Motor Start jumper is not connected)  
Disable the Delay Motor Start option (default).  
Motor start delay equal to the SCSI ID multiplied  
by 10 seconds. For example, if the SCSI ID = 2,  
the drive starts in 20 seconds.  
Figure 15a. Jumper options  
 
46  
Barracuda 2LP Installation Guide, Rev. E  
WC/DC drives  
Pin 1  
J2  
J4  
(front view of J4)  
Pin 1  
J4  
Pin 2  
Pin 1  
SCSI ID = 0  
Fault LED pin (–)  
SCSI ID = 1  
Vendor Unique  
SCSI ID = 2  
SSREF (+)  
SCSI ID = 3  
Unit Active LED pin (–)  
Not used  
Ground  
+5 volts  
Not connected  
Reserved  
Figure 15b. Additional jumper options  
 
 
 
 
Seagate Technology, Inc.  
920 Disc Drive, Scotts Valley, CA 95066-4544, USA  
Publication Number: 83328920, Rev. E, Printed in USA  
 

PYLE Audio Stereo Amplifier PAMP1000 User Guide
Radio Shack Conference Phone TAD 705 User Guide
Ramsey Electronics Weather Radio rrw1b User Guide
RCA Clock Radio RC10 User Guide
Renesas Network Card M16C PC4701 User Guide
ResMed Sleep Apnea Machine S8 User Guide
Ryobi Edger P2005 User Guide
Samsung DVD Player DVD AR650 User Guide
Samsung TV Antenna T24D390SW User Guide
Sears Refrigerator 51271 User Guide