Troubleshooting
INSTALLATION AND OPERATING INSTRUCTIONS
UNIVERSAL EMPTY KEG SENSOR
Problem:
Beer flow is slower with Universal Empty Keg Sensor
than with standard Perlick coupler.
Probable Cause: Beer Flow Control Handle is in CLEAN position.
Part No.
Solution:
Slowly turn Beer Flow Control Handle to ON position.
■ 43739
Problem:
Beer does not flow after keg is tapped.
Probable Cause: Universal Empty Keg Sensor has locked up.
The Perlick Universal Empty
Keg Sensor shuts off the flow
of beer when the keg empties.
With the line full of beer, the
foaming and resulting beer
waste from changing kegs is
eliminated.
Solution:
Turn Beer Flow Control Handle to OFF position.
Wait two or three seconds than slowly turn Beer Flow
Control Handle to ON position.
Probable Cause: Beer Flow Control Handle is OFF.
Solution:
Slowly turn Beer Flow Control Handle to ON position.
Probable Cause: Universal Empty Keg Sensor is dirty.
Solution:
Clean Universal Empty Keg Sensor.
Probable Cause: Out of gas.
Solution:
Problem:
Reestablish gas flow.
Excessive foam.
Probable Cause: Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated
Solution:
These problems are not caused by the Universal Empty
Keg Sensor. Follow established procedures to correct
the problem.
No. 43739
Universal Empty
Keg Sensor
IMPORTANT!
To ensure your complete satisfaction, please read these instructions
before using Perlick’s Universal Empty Keg Sensor.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Form Z2148EMU
08.20.04
* U.S. Patent #5,630,411
|